Revolutionary Real-time Full Analysis Remote Display

In large foundries and steel plants, the melting platform and the laboratory are quite often removed from each other by as much as a few hundred meters. The latest wireless RTDS system enables results to be transmitted seamlessly from the lab to the melting platform on a real-time basis.

Enquiry Download Brochure Enquiry

The Best Possible Protection

In several markets, the quality of power supply remains poor. We recognize the need to protect our customers from expensive repairs that could result from faults caused by such issues. Armour Safe protects your Spectrometer Systems (and any other connected equipment) from a variety of issues including short circuits, over voltage, high surge, earth leakage etc. Armour Safe offers fault indications as well, ensuring the best possible protection for your expensive equipment.

Enquiry Download Brochure Enquiry

For better analysis

Argon gas comes in different grades. Thus, there could be Grade 4.8 which would be 99.998% pure. Grade 5.0 would be 99.999% pure. To get good and repeatable analyses, the Argon gas should be at least 99.999% pure. The extent and type of impurities are also important. Moisture and Oxygen contribute the most to poor analysis. Normally, moisture and oxygen should be controlled to be within 2 ppm each. The more critical the application, the more pure the Argon Gas should be. Especially, when we analyse extra hard samples like chill cast cast irons (with high C & Si etc.) the purity has to be of an even better level. In some cases, customers face issues with the quality of Argon being used. In these cases, the moisture, Oxygen and / or hydrocarbon levels may exceed those that are needed for high-end analysis – and which should be availed of in UHP Argon. In such cases, there is a risk posed to analytical performance and also the optics components themselves – as these are sensitive to impure Argon (Argon that is not of UHP level as required). Metal Power’s Argon Purifer+ enables users to purify Argon gas and frees it from oxygen, moisture and hydrocarbons to acceptable levels if the input Argon gas is not of a high enough quality. To keep the pressure output stable, a clean technology pressure regulator is used inside the Argon Purfier+. Ths ensures that constant pressure is applied at all times to the OES for avoiding ripples. Argon Purifier+ therefore helps: • Improves analytical reproducibility • Improves the quality of burns • Reduces drift • Safeguards the OES

Enquiry Download Brochure Enquiry

The Brushless Wonder

Metal Power’s CleanSharp – the Brushless Electrode Cleaner-Sharpener – helps make electrode tip cleaning and pointing easy, safe, quick & much better! Using CleanSharp to clean the unwanted metal residue from the electrode tip is not only simple, but also extremely effective. CleanSharp is light and compact (Weight: 375 grams, Length x Dia.: 170 mm x 40 mm) and the sturdy design and stainless steel construction make the Electrode Sharpener extremely robust and safe from external dust, making it the perfect tool to have in heavy industries. The CleanSharp also does not erode the Petrey/Base Plate hole and saves a lot of money. Brushes have been found to be very notorious in this regard. The smartly designed safety cap provided at the tip of the CleanSharp not only safeguards the sharpener bit from damage but can be also used as a Gap Setting Tool for all Spectrometers, maintaining a precise gap for excellent results. Easily replaceable sharpening bits for electrodes of different diameters and cone angles are also available. CleanSharp is easy to use and fits beautifully in the palm of your hand. Requiring zero maintenance, CleanSharp adds tremendous value, specially to users with high sample throughput.

Enquiry Download Brochure Enquiry

The Ultimate Storage Solution

A lot of things go into helping your OES work optimally. There is a multitude of items that you would have to keep at hand, including Setting-up Samples (SUS), Certified Reference Materials (CRMs), consumables, tool bits and allen keys as well as things such as DOs and DON’Ts, troubleshooting guides, manuals, the odd spares etc. The Handyman has been designed specifically for OES customers, with minute attention paid to each aspect of storage, ergonomics, security and aesthetics. With clearly marked storage compartments for each item of need, a lockable section for high-value / sensitive items and a colour palette to match the unit to your OES (and Lab), the Handyman is the ultimate storage solution for all the accessories you use to optimize the working of your OES.

Enquiry Enquiry

Wire Adaptors

Metal Power’s Standard Wire Adapters are designed to analyze wires and wire rods from 2mm to 13mm in diameter. On the Metavision-10008X and Metavision-1008i3, we also other the patented wire analysis application that extends this capability down to as low as 0.1 mm diameter.

Enquiry Enquiry

Sampling Moulds

A range of long-life Sampling moulds are offered for sampling from the furnace/ladle. The choice of mould depends on the molten metal to be sampled.

Enquiry Enquiry

Have Questions? Contact us


        Copyright © 2022 All Rights Reserved. Metal Power Analytical Pvt. Ltd.
        >>>>>>>>